Facebook

PAHs Testing for Neoprene Foam Material

Neoprene Foam and PAHs Chemical Testing

MICOOSON provides material information and technical documentation for customers evaluating Neoprene and related synthetic materials.

For material buyers, chemical testing documentation can help support purchasing decisions and evaluation against specific customer requirements.

MICOOSON has third-party PAHs testing documentation for a submitted sample identified as Neoprene.

The tested component was described as black middle foam. The report covers eight selected polycyclic aromatic hydrocarbons.

What Are PAHs?

PAHs stands for Polycyclic Aromatic Hydrocarbons, a group of chemical compounds that may be relevant to the chemical safety assessment of certain materials.

PAHs screening is used to investigate specified substances in submitted samples using laboratory analytical methods.

For Neoprene foam buyers, PAHs testing documentation can provide information about selected chemical substances in a tested material component.

The presence or absence of specified PAHs must be interpreted according to the laboratory's reporting limits and testing scope.

What Is AfPS GS 2019:01 PAK?

AfPS GS 2019:01 PAK is a testing specification referenced in the laboratory report for the analysis of selected polycyclic aromatic hydrocarbons.

The submitted Neoprene foam component was tested with reference to AfPS GS 2019:01 PAK using gas chromatography-mass spectrometry (GC-MS).

The use of this method does not automatically mean that the product has obtained GS certification.

Buyers should verify the testing scope and applicable requirements for their particular products.

Neoprene Foam PAHs Test Report Information

The test documentation identifies the following details:

  • Report Number: SL92509284252001TX

  • Report Date: March 13, 2025

  • Sample Description: Neoprene

  • Tested Component: Black middle foam

  • Test Item: Polycyclic Aromatic Hydrocarbons (PAHs)

  • Reference Test Method: AfPS GS 2019:01 PAK

  • Analytical Method: GC-MS

  • Number of Reported PAHs: Eight

  • Reporting Limit: 0.10 mg/kg for each listed PAH

  • Reported Requirement: 1 mg/kg for each listed PAH

  • Overall Conclusion: Pass

The findings relate to the specific submitted component and tested substances.

They should not be interpreted as confirmation that every Neoprene product or component supplied by MICOOSON has the same chemical testing results.

PAHs Screening Results for Black Neoprene Foam

The report includes testing for the following eight substances:

  • Benzo(a)pyrene (BaP)

  • Benzo(e)pyrene (BeP)

  • Benzo(a)anthracene (BaA)

  • Benzo(b)fluoranthene (BbF)

  • Benzo(j)fluoranthene (BjF)

  • Benzo(k)fluoranthene (BkF)

  • Chrysene (CHR)

  • Dibenzo(a,h)anthracene (DBA)

All eight substances were reported as ND (Not Detected), with a reporting limit of 0.10 mg/kg for each substance.

The laboratory report records a Pass conclusion for the tested component against the requirements shown in the report.

ND indicates that the substance was not detected at or above the applicable reporting limit. It does not prove that the material contains absolutely no PAHs.

Why Is PAHs Testing Important for Neoprene Materials?

Neoprene materials can contain different layers or components depending on their construction.

Chemical testing results may therefore be specific to a selected component rather than the entire finished material.

When sourcing Neoprene foam materials, buyers should consider:

  • Material construction and component layers

  • Foam material specifications

  • Intended product application

  • Relevant chemical testing requirements

  • PAHs screening scope

  • Individual substance reporting limits

  • Sample and component identification

  • Applicable customer requirements

  • Production batch traceability

  • Additional testing requirements for other components

The results of laboratory testing should be reviewed together with the specifications of the intended finished product.

Is PAHs Testing the Same as GS Certification?

No.

PAHs testing provides chemical analytical results for specified substances in a tested sample.

GS certification involves a separate conformity assessment process and cannot be established solely from a PAHs test report.

The available MICOOSON documentation records PAHs test results for a black Neoprene foam component and should not be described as GS product certification.

Neoprene Material Supplier – MICOOSON

Customers evaluating Neoprene materials can contact MICOOSON to discuss product specifications, available samples and technical documentation.

Buyers should confirm whether the tested foam component corresponds to the exact material construction and production batch being purchased.

If their project requires evaluation of additional layers or chemicals, separate testing may be necessary.

Frequently Asked Questions

Does MICOOSON Have PAHs Testing Documentation for Neoprene?

Yes. MICOOSON has third-party PAHs testing documentation for a submitted Neoprene sample, specifically its black middle foam component.

What Does PAHs Stand For?

PAHs stands for Polycyclic Aromatic Hydrocarbons.

Which Test Method Was Referenced?

The laboratory report references AfPS GS 2019:01 PAK, with analysis performed by GC-MS.

How Many PAHs Were Included in the Report?

The report lists eight selected PAHs.

What Were the Reported PAHs Results?

All eight listed PAHs were reported as ND, with a reporting limit of 0.10 mg/kg.

Does ND Mean the Neoprene Foam Is Completely PAHs-Free?

No. ND means the substances were not detected at or above the specified reporting limits.

Does This Report Mean the Neoprene Material Is GS Certified?

No. The report documents specified PAHs testing and does not constitute GS product certification.

Does the Testing Cover the Entire Neoprene Material?

The test results refer to the black middle foam component identified in the report. They should not automatically be applied to every layer of the material.

Does This Report Cover All MICOOSON Neoprene Materials?

No. It applies to the specific submitted sample and tested component.

Can Buyers Request PAHs Testing Documentation?

Customers can contact MICOOSON to enquire about available material information and testing documentation, subject to applicable report-use restrictions.

Contact MICOOSON for Neoprene Material Information

Looking for Neoprene foam materials and information about PAHs chemical testing?

Contact MICOOSON to discuss your material specifications, product sample requirements and available technical documentation.

Explore MICOOSON Material Test Reports