Facebook

Hypalon Material Heavy Metal Testing – Lead, Mercury, Cadmium and Chromium

Heavy Metal Testing Information for Hypalon Material

MICOOSON provides synthetic material information and technical documentation for customers evaluating chemical testing requirements.

For material buyers, information about restricted heavy metals can support purchasing decisions and material compliance assessments.

MICOOSON has third-party heavy metal testing documentation for a submitted sample identified as Hypalon.

The submitted sample was black and the tested component was described as a black solid sheet with a brown line.

The report covers four substances: lead, mercury, cadmium and hexavalent chromium.

What Is RoHS Heavy Metal Testing?

RoHS stands for Restriction of Hazardous Substances.

The EU RoHS Directive 2011/65/EU and its amendments establish restrictions on specified hazardous substances in certain electrical and electronic equipment.

Heavy metal testing can provide information about the concentration of selected restricted substances in a submitted material.

However, testing four heavy metals does not automatically establish complete RoHS compliance for an entire product.

Buyers should consider the intended product application, applicable regulations and any additional testing requirements.

Hypalon Heavy Metal Test Report Information

The test report identifies the following details:

  • Report Number: SHARS25028526201

  • SGS Job Number: SHRT25000654

  • Report Date: November 5, 2025

  • Sample Name: Hypalon

  • Color: Black

  • Tested Component: Black solid sheet with brown line

  • Test Items: Lead, Mercury, Cadmium and Hexavalent Chromium

  • Regulatory Reference: EU RoHS Directive 2011/65/EU, as amended by Directive (EU) 2015/863

  • Analytical Methods: IEC 62321 series

  • Analysis Techniques: ICP-OES/AAS and UV-Vis

The findings apply to the specific submitted material and tested component.

They do not constitute certification of every Hypalon material supplied by MICOOSON.

Lead (Pb) Test Result

The report records a lead concentration of 5 mg/kg in the submitted material.

The referenced RoHS limit for lead was 1,000 mg/kg.

The method detection limit for lead was 2 mg/kg.

The reported lead concentration was below the specified limit.

Importantly, lead was detected at 5 mg/kg. Therefore, the tested sample should not be described as completely lead-free.

Mercury, Cadmium and Hexavalent Chromium Test Results

The report provides the following findings:

  • Mercury (Hg): ND, method detection limit 2 mg/kg

  • Cadmium (Cd): ND, method detection limit 2 mg/kg

  • Hexavalent Chromium (Cr(VI)): ND, method detection limit 8 mg/kg

The report lists the following reference limits:

  • Mercury: 1,000 mg/kg

  • Cadmium: 100 mg/kg

  • Hexavalent Chromium: 1,000 mg/kg

All three reported ND results were below their corresponding reference limits.

ND means Not Detected at the stated method detection limit. It does not establish the complete absence of a substance.

Does This Report Confirm Full RoHS Compliance?

No. The laboratory report covers four specific heavy metal test items.

RoHS restrictions also address additional substances not included in this report.

The reported heavy metal results were below the corresponding limits listed in the document, but this does not establish complete compliance of every finished product with all applicable RoHS requirements.

Additional evaluation may be necessary depending on the intended use of the material.

Why Is Heavy Metal Testing Important for Synthetic Materials?

Material buyers may request heavy metal testing information when evaluating materials intended for regulated or customer-specific applications.

When selecting Hypalon or similar synthetic materials, buyers should consider:

  • Material grade and composition

  • Intended product application

  • Applicable restricted substance requirements

  • Lead concentration

  • Mercury and cadmium testing

  • Hexavalent chromium testing

  • Analytical detection limits

  • Tested sample identification

  • Additional chemical testing requirements

  • Production batch traceability

A laboratory report should be assessed together with the relevant product specifications and regulatory obligations.

Hypalon Material Supplier – MICOOSON

MICOOSON provides technical material information for customers evaluating synthetic materials and related testing requirements.

Customers interested in Hypalon materials can contact MICOOSON to discuss product specifications, sample availability and technical documentation.

Buyers should verify that the available test report corresponds to the exact material grade and production batch being purchased.

Frequently Asked Questions

Does MICOOSON Have Heavy Metal Testing Documentation for Hypalon?

Yes. MICOOSON has third-party testing documentation for a submitted black Hypalon sample covering lead, mercury, cadmium and hexavalent chromium.

What Was the Reported Lead Content?

The test report records 5 mg/kg of lead in the tested component, below the referenced limit of 1,000 mg/kg.

Was Mercury Detected?

Mercury was reported as ND at a method detection limit of 2 mg/kg.

Was Cadmium Detected?

Cadmium was reported as ND at a method detection limit of 2 mg/kg.

Was Hexavalent Chromium Detected?

Hexavalent chromium was reported as ND at a method detection limit of 8 mg/kg.

Is the Hypalon Material Completely Lead-Free?

No. The report records a measurable lead concentration of 5 mg/kg.

Does This Test Report Cover All RoHS Restricted Substances?

No. The document provides results for four heavy metals and does not cover every substance restricted under RoHS.

Is This Report a RoHS Product Certification?

No. It is a material test report covering specified chemical substances. It does not automatically certify a finished product.

Does This Report Apply to Every MICOOSON Hypalon Product?

No. The findings apply only to the submitted sample and documented testing conditions.

Can Buyers Request Heavy Metal Test Documentation?

Customers can contact MICOOSON to discuss material specifications and available technical documentation, subject to applicable report-use restrictions.

Contact MICOOSON for Hypalon Material Information

Looking for Hypalon materials with relevant heavy metal testing information?

Contact MICOOSON to discuss material specifications, intended applications, product samples and available technical documentation.

Explore MICOOSON Material Test Reports

Explore PAHs Testing for Neoprene Foam Materials